ORLAN/ORLAN SUPER

Wood gasification



Wood is a widely available fuel and also one of the least expensive resources. In the correct wood combustion process small amounts of harmful substances are produced, such as NOx, CO, Hydrocarbons, breathable dust and the amount of ash produced is about 1% of the mass of the fuel load (this depends on the dust content of the wood).

Orlański's wood gasification boilers are adapted to wood of various particlesize distribution: wood logs, logs and chips. Sawdust and chips should be burned along with wood logs. Technical parameters resulting from wood combustion processes meet the most rigorous European norms and provide nearly twice as much heat as traditional boilers or fireplaces. The appliances can work in open as well as pressurized systems in accordance with current regulations.

 Use

ORLAN SUPER (18-80kW) boilers are designed for heating various types of buildings. They are commonly used in detached houses, drying facilities, industrial units and workshops.

ORLAN SUPER 96 or 130kW boilers allow the heating of larger areas such as large industrial buildings or public facilities.

 
 Fuel used

Stages of gasification process

Advantages

 
  • Up to 91% effi cient
  • Range from 18 to 130kW
  • Large loading capacity
  • Length of wood logs:
    - 50cm (18kW, 25kW, 40kW)
    - 75cm (60kW)
    - 100cm (80kW, 95kW, 130 kW)
  • Small amount of ash residue
  • Low maintenance costs
  • User-friendly construction
  • Up to 12 hours continuous operation
  • Modulated fan power 30-100%
  • Adjusted to work in pressurized systems thanks to cooling coil installed in upper part of boiler body
 
  • Electronic controller with possibility to connect remote EKOSTER CONTROL
  • Made from the highest quality 6mm steel
  • Environmentally-friendly – almost zero CO
  • Half-round fi regrate
  • Two inner boiler flues of 180 mm
  • Two cleaning mechanisms from left and right side of the boiler
  • Extra lever on the right side for ease of opening of boiler flaps

 

How do I know which boiler is suitable for me?

 

   
  • An installation designer will estimate how much heat heat will be required in the building.

  •  The result needs to be increased by 20% (so called boiler over-sizing).

  • See the graph opposite for to give an indication of the correct boiler that may be suitable.

 

Caution!
The graph is for information only and ORLANSKI cannot be held liable if a boiler with unsuitable power output is selected.

 

Boiler construction


ORLAN


    1. Hot water outlet
  2. Boiler controller
  3. Loading door
  4. Fan
  5. Fan casings
  6. Combustion door
    7. Firebricks
  8. Combustion chamber
  9. Tube heat exchanger
10. Nozzle
11. Ceramic moulders
12. Cooling coil



ORLAN SUPER

 

 

    1. Hot water outlet
  2. Pocket for cooling valve sensor
  3. Boiler controller
  4. Loading door
  5. Fans
  6. Fan casings
  7. Combustion door
  8. Firebricks
  9. Air pipes
10. Combustion chamber
 
11. Return water outlet
12. Tube heat exchanger
13. Ceramic moulders
14. Loading (gasification) chamber
15. Cleaning mechanism
16. Chimney flue
17. Flue flaps
18. Cooling coil
19. Cleaning mechanism lever
20. Cooling coil tappings

 

 

Technical specification

Rated power [kW] 18 25 40 60 80 96 130
    Power range [kW] 7-18 10-25 16-40 24-60 32-80 38,4-96 52-130
    Efficiency [%] 91       90,5   91
    Boiler class (EN 303-5) 3
    Water capacity [dm³] 55 75 93 180 205 340 380
    Water capacity [l] 55 75 93 180 205 340 380
    Water capacity in the boiler
    (gasification) [dm³]
85 120 185 310 465 605 605
    Water capacity in the boiler
    (gasification) [l]
85 120 185 310 465 605 605
    Loading slot size width/length [mm] 225/380  260/432  260/432  285/580   285/580  285/580  285/580
    Burning period [h] 7-12 
    Length of wooden blocks [cm]  50  50  50  75  100  100  100
    Humidity – recommended [%]  15-25
    Average fuel usage for:
    - nominal power [kg/h]  6,8 8,2  10,1  15,1  19,8  20,3 24,5
    Maximum operating pressure [bar]  3
    Miniumum temperature of the return [°C]  60
    Temperature settings range [°C]  60-97
    Protection level  IP40
    Voltage/Frequency [V/Hz] 230/50 
    Fumes features (at nominal power):
    - fumes temerature [°C] 150-180  150-180  150-180  150-180   150-180 160-180 160-180
    - fumes fow [kg/s]  0,0066  0,0088  0,0144 0,0216   0,0272 0,0332 0,0332
     Required chimney draught [Pa]  15-20  15-25 15-20 
     Cooling water pressure required
     at the infux to a heat exchanger [bar]
 2
     Cold water temperature in   the heat
     exchanger [°C]
 10
     Recommended capacity
     of accumulation tank [l]
750-1500  1000-2000  2000-3000   3000-4000  4000-5000 4000-5000 5000-6000

 

Dimensions

 

 

Dimensions

  Boiler type [kW] 18 25 40 60 80 96 130
    Total height [A - mm] 1220 1320 1570 1540 1540 1845 1845
    Hot water outlet (overall height) [B - mm] 1210 1300 1560 1575 1590 1845 1845
    Return water inlet [C - mm]  210 230   220  200 200 209 209
    Waste outlet height [D - mm] 140 140   140 140   140 134 134
    Chimney conduit height [E - mm] 870 960 1210  1160   1170 1441 1441
    Casing width [G - mm] 545 600 600  740 740 750 750
    Total depth [H - mm] 960  1040   1040 1340  1700 1804 1880
    Hot water outlet [I -mm]  340  310 300 570 600 734 798
    Chimney conduit diameter [J - mm]  180  200  200 210  210  300 300
    Total width [K - mm]  660  720 720   860  860 870 870
    Height of coil connection [L - mm]  990  1100 1330  1310  1300 1310 1310
    Coil outlet [M - inch] 260 150 260 210 300 313 313
    Diameter of feeding and return ferrule [Q - inch] 2 2 2 2 2 2 2
    Diameter of coil ferrules [R - inch] 3/4 3/4 3/4 3/4 3/4 1 1
    Diameter of blowdown connection [S - inch] 1/2 1/2 1/2 1/2 1/2 3/4 3/4

 

 

 

Controller

 

The EKOSTER 2 microprocessor temperature controller is designed to control the heating process and the activation of the circulation pump in the central heating installation.
 

 

 

EKOSTER controller used in the
ORLAN boiler

 

Controller features

 

The regulator fulfi ls the following tasks:

  • Maintains the preset boiler temperature through the heating control
  • Automatic control turn-off after boiler extinction 
  • Blocking fan operation when stoking to the boiler 
  • Central heating circulation pump control “COMFORT SYSTEM”– a system that prevents pump blockages when the boiler is not in operation overheating
  • Protection from boiler freezing and overheating 
  • Signalling when the boiler temperature sensor is damaged
  • Compatible with EKOSTER control remote control system

 

 

 