KSW Master

 

Fired with fine coal and solid fuels

The innovative design of the furnace of the KSW Master boiler, additionally equipped with blow-in system 1 allows the use of most solid fuels for firing. The application of the water pocket system effectively lengthens the flue gas circulation 2 thus enhancing boiler efficiency. This boiler stands out thanks to its effective combustion of fine coal and an the option of firing up from the top and from the bottom.

 

High temperature without the risk of overheating

Boiler operation is supported by an electronic controller 3. It controls the fan operation 4 located in the upper part of the boiler, reduces fuel consumption by 10-30% and extends working time with a single charge. It maintains high temperatures in the boiler without the risk of overheating.

 

 

Robust design

The KSW Master boiler was designed with the aim of operating efficiently and reliably for many years. Its long operational life is guaranteed by its design – especially its solid plates combined with double welds. This model is covered by the following warranty terms: 2-year warranty for subassemblies, 5-year warranty for heat exchanger tightness and 10-warranty for weld density.


Easier day-to-day operations

Each batch-fed boiler requires daily maintenance. Therefore we have done our best to facilitate day-to-day boiler operations to the maximum. We widened the firing door 5 to improve the feeding of fuel and cleaning of the combustion chamber. On the side of the boiler, there is a grate lever 6, that allows with a single push to let the ash drop into the ash pan 7, from where it can be easily removed. We are one of the few boiler producers that offers the option of firing door horizontal adjustment to retain their air-tightness.

 

 

Technical data

PARAMETER Type
12 16 18 20 24 30
    Dimensions   D [mm] 159 178
  E [mm] 248 × 173 298 × 198 348 × 248
  L [mm] 425 495 525 590 
  L1 [mm] 45
  L2 [mm] 190 220
  H [mm] 1170 1265   1270  1360 1385
  H1 [mm] 1005  1090 1080 1175 1200
  H2 [mm] 235
  S [mm] 390 440 550
  S1 [mm]  65
    Basic fuel Hard coal, fine coal
    Heating power* [kW] 12 16 18 20 25 30
    Area of heated rooms** [m²] 120 150 180 200   240 290
    Cubature of heated rooms [m³] 300 375 450 500 600 725
    Efficiency [%] ~80 – 85
    Range of power regulation [%] ±2
    Capacity of combustion chamber [dm³] 32 37 42 50 60 90
    Water capacity of boiler [dm³] 40 54 57 72  80 105
    Heat exchanger material   P265GH [PN-EN 10028] steel; 6 mm
    Maximum working pressure [bar] 1.5
    Requested minimum chimney draught*** [Pa] 23 25 
    Water temperature min./max. [°C] 57/95
    Power supply / Power [V/W] 230/85
    Boiler weight without water [kg] 210 230 245 275 290 350
    Water tubular diameter [cal] G 1 1/2

 

*Maximal water temperature in the boiler – 95°C;
**For rooms of the height of up to 2.5 m;
***PN-EN 12809, PN-EN 303-5:2002;

 

 

 